Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 161
Filtrar
1.
Heart Rhythm ; 2024 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-38614189

RESUMO

BACKGROUND: A rare gene variant in SCN5A can be found in approximately 20-25% of patients with Brugada syndrome (BrS). OBJECTIVE: The aim of this systematic review and meta-analysis is to evaluate: (1) differences in clinical characteristics of BrS patients with and without SCN5A rare variants and (2) the prognostic role of SCN5A for ventricular arrhythmias in BrS. METHODS: PubMed and Cochrane Central Register of Controlled Trials (CENTRAL) were systematically searched from inception to January 2024 to identify all relevant studies. Studies were analyzed if including patients diagnosed with BrS in whom genetic testing for SCN5A variants was performed and arrhythmic outcomes were reported. RESULTS: A total of 17 studies with 3568 BrS patients, of whom 3030 patients undergone to genetic testing for SCN5A variants, fulfilled the eligibility criteria and were included. Compared with SCN5A- patients, SCN5A+ BrS patients had more frequently spontaneous type I ECG, history of syncope and documented arrhythmias. Furthermore, higher PQ and QRS intervals in SCN5A+ BrS patients, compared with SCN5A- have been found. The pooled analysis demonstrated a significant association between the presence of SCN5A rare variants in BrS patients and the risk of MAEs, with a pooled OR of 2.14 (95% CI: 1.53; 2.99, I2 = 29%). CONCLUSION: SCN5A+ BrS patients showed a worse clinical phenotype compared with SCN5A-. The pooled analysis demonstrated a significant association between SCN5A+ mutation status and the risk of MAEs in BrS patients.

2.
Circ Arrhythm Electrophysiol ; 17(4): e012374, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38426305

RESUMO

BACKGROUND: A pathogenic/likely pathogenic variant can be found in 20% to 25% of patients with Brugada syndrome (BrS) and a pathogenic/likely pathogenic variant in SCN5A is associated with a worse prognosis. The aim of this study is to define the diagnostic yield of a large gene panel with American College of Medical Genetics and Genomics variant classification and to assess prognosis of SCN5A and non-SCN5A variants. METHODS: All patients with BrS, were prospectively enrolled in the Universitair Ziekenhuis Brussel registry between 1992 and 2022. Inclusion criteria for the study were (1) BrS diagnosis; (2) genetic analysis performed with a large gene panel; (3) classification of variants following American College of Medical Genetics and Genomics guidelines. Patients with a pathogenic/likely pathogenic variant in SCN5A were defined as SCN5A+. Patients with a reported variant in a non-SCN5A gene or with no reported variants were defined as patients with SCN5A-. All variants were classified as missense or predicted loss of function. RESULTS: A total of 500 BrS patients were analyzed. A total of 104 patients (20.8%) were SCN5A+ and 396 patients (79.2%) were SCN5A-. A non-SCN5A gene variant was found in 75 patients (15.0%), of whom, 58 patients (77.3%) had a missense variant and 17 patients (22.7%) had a predicted loss of function variant. At a follow-up of 84.0 months, 48 patients (9.6%) experienced a ventricular arrhythmia (VA). Patients without any variant had higher VA-free survival, compared with carriers of a predicted loss of function variant in SCN5A+ or non-SCN5A genes. There was no difference in VA-free survival between patients without any variant and missense variant carriers in SCN5A+ or non-SCN5A genes. At Cox analysis, SCN5A+ or non-SCN5A predicted loss of function variant was an independent predictor of VA. CONCLUSIONS: In a large BrS cohort, the yield for SCN5A+ is 20.8%. A predicted loss of function variant carrier is an independent predictor of VA.


Assuntos
Síndrome de Brugada , Humanos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/genética , Testes Genéticos , Arritmias Cardíacas/genética , Mutação de Sentido Incorreto , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Mutação
3.
Heart Rhythm O2 ; 5(2): 137-144, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38545325

RESUMO

Background: Pericarditis is the most common complication following hybrid sinus node-sparing ablation for inappropriate sinus tachycardia (IST)/postural orthostatic tachycardia syndrome (POTS). Objective: The study sought to evaluate the association of prophylaxis therapy on the risk of symptomatic pericarditis following hybrid IST/POTS ablation. Methods: All consecutive patients undergoing to hybrid ablation of symptomatic IST/POTS refractory or intolerant to drugs were retrospectively analyzed. Pharmacological prophylaxis therapy was based on acetylsalicylic acid and colchicine started on the day of the ablation and continued for at least 3 months. The primary endpoint was occurrence of symptomatic pericarditis. The secondary endpoint was occurrence of pericarditis-related complications, including the following: duration of pericarditis >3 months, hospitalization for pericarditis, postpericardiectomy pleuro-pericarditis, and pericardiectomy. Results: A total of 220 patients undergone to hybrid IST/POTS ablation were included and 44 (20%) underwent prophylaxis therapy. Pericarditis occurred in 101 (45.9%) patients, with 97 (96%) in the first 5 days. At survival analysis, prophylaxis was associated with higher rate of freedom from pericarditis (81.9% vs 47.2%, log-rank P < .001). Pericarditis-related complications were low, occurring in 7 (3.2%) patients. There was no difference in pericarditis-related complications between the patients who underwent prophylaxis therapy and patients who did not. At Cox multivariate analysis, predictors of pericarditis were IST (vs POTS) (hazard ratio 0.61, 95% confidence interval0.39-0.99, P = .04) and prophylaxis therapy (hazard ratio 0.27, 95% confidence interval 0.13-0.55, P < .001). Conclusion: In a large cohort of patients undergoing hybrid ablation for IST/POTS, a prophylaxis therapy with acetylsalicylic acid and colchicine was associated with a lower rate of symptomatic pericarditis.

5.
Heart Rhythm ; 2024 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-38290688

RESUMO

BACKGROUND: Pulsed field ablation (PFA) is selective for the myocardium. However, vagal responses and reversible effects on ganglionated plexi (GP) are observed during pulmonary vein isolation (PVI). Anterior-right GP ablation has been proven to effectively prevent vagal responses during radiofrequency-based PVI. OBJECTIVE: The purpose of this study was to test the hypothesis that PFA-induced transient anterior-right GP modulation when targeting the right superior pulmonary vein (RSPV) before any other pulmonary veins (PVs) may effectively prevent intraprocedural vagal responses. METHODS: Eighty consecutive paroxysmal atrial fibrillation patients undergoing PVI with PFA were prospectively included. In the first 40 patients, PVI was performed first targeting the left superior pulmonary vein (LSPV-first group). In the last 40 patients, RSPV was targeted first, followed by left PVs and right inferior PV (RSPV-first group). Heart rate (HR) and extracardiac vagal stimulation (ECVS) were evaluated at baseline, during PVI, and postablation to assess GP modulation. RESULTS: Vagal responses occurred in 31 patients (78%) in the LSPV-first group and 5 (13%) in the RSPV-first group (P <.001). Temporary pacing was needed in 14 patients (35%) in the LSPV-first group and 3 (8%) in the RSPV-first group (P = .003). RSPV isolation was associated with similar acute HR increase in the 2 groups (13 ± 11 bpm vs 15 ± 12 bpm; P = .3). No significant residual changes in HR or ECVS response were documented in both groups at the end of the procedure compared to baseline (all P >.05). CONCLUSION: PVI with PFA frequently induced vagal responses when initiated from the LSPV. Nevertheless, an RSPV-first approach promoted transient HR increase and reduced vagal response occurrence.

6.
J Interv Card Electrophysiol ; 67(2): 273-283, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37103590

RESUMO

BACKGROUND: Posterior wall (PW) isolation is an important adjunctive ablation target in patients with non-paroxysmal atrial fibrillation (AF). Traditionally performed with point-by-point radiofrequency (RF) ablation, PW isolation has also been performed with different cryoballoon technologies. We aimed at assessing the feasibility of PW isolation with the novel RF balloon catheter Heliostar™ (Biosense Webster, CA, USA). METHODS: We prospectively enrolled 32 consecutive patients with persistent AF scheduled for first-time ablation with the Heliostar™ device. Procedural data were compared with those from 96 consecutive persistent AF patients undergoing pulmonary vein (PV) plus PW isolation with a cryoballoon device. The ratio RF balloon/cryoballoon was 1:3 for each operator involved in the study, aiming at avoiding any imbalance related to different experience. RESULTS: Single-shot PV isolation was documented in a significantly higher number of cases with the RF balloon technology compared to cryoballoon ablation (89.8% vs. 81.0%; p = 0.02, respectively). PW isolation was achieved with a similar number of balloon applications between the two groups (11 ± 4 with the RF balloon versus 11 ± 2 with the cryoballoon; p = 0.16), but in a significantly shorter time among RF balloon patients (228 ± 72 s versus 1274 ± 277 s with cryoballoon; p < 0.001). Primary safety endpoint occurred in none of the RF balloon patients versus 5 (5.2%) patients in the cryoballoon group (p = 0.33). Primary efficacy endpoint was achieved in all (100%) RF balloon patients versus 93 (96.9%) cryoballoon ones (p = 0.57). Oesophageal endoscopy did not show any signs of thermal lesions in RF balloon patients with luminal temperature rise. CONCLUSIONS: RF balloon-based PW isolation was safe and promoted shorter procedure times compared to similar cryoballoon-based ablation procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Criocirurgia/métodos , Estudos de Viabilidade , Resultado do Tratamento , Ablação por Cateter/métodos , Recidiva , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Cateteres
7.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38064697

RESUMO

AIMS: Catheter ablation (CA) is an established treatment for atrial fibrillation (AF). A computed tomography (CT) may be performed before ablation to evaluate the anatomy of pulmonary veins. The aim of this study is to investigate the prevalence of patients with coronary artery disease (CAD) detected by cardiac CT scan pre-ablation and to evaluate the impact of CAD and revascularization on outcomes after AF ablation. METHODS AND RESULTS: All consecutive patients with AF diagnosis, hospitalized at Universitair Ziekenhuis Brussel, Belgium, between 2015 and 2019, were prospectively screened for enrolment in the study. Inclusion criteria were (i) AF diagnosis, (ii) first procedure of AF ablation with cryoballoon CA, and (iii) contrast CT scan performed pre-ablation. A total of 576 consecutive patients were prospectively included and analysed in this study. At CT scan, 122 patients (21.2%) were diagnosed with CAD, of whom 41 patients (7.1%) with critical CAD. At survival analysis, critical CAD at CT scan was a predictor of atrial tachyarrhythmia (AT) recurrence during the follow-up, only in Cox univariate analysis [hazard ratio (HR) = 1.79] but was not an independent predictor in Cox multivariate analysis. At Cox multivariate analysis, independent predictors of AT recurrence were as follows: persistent AF (HR = 2.93) and left atrium volume index (HR = 1.04). CONCLUSION: In patients undergoing CT scan before AF ablation, critical CAD was diagnosed in 7.1% of patients. Coronary artery disease and revascularization were not independent predictors of recurrence; thus, in this patient population, AF ablation should not be denied and can be performed together with CAD treatment.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Doença da Artéria Coronariana , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/cirurgia , Resultado do Tratamento , Átrios do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva
8.
Europace ; 26(1)2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38155611

RESUMO

AIMS: A novel sinus node (SN) sparing hybrid ablation for inappropriate sinus node tachycardia (IST)/postural orthostatic tachycardia syndrome (POTS) has been demonstrated to be an effective and safe therapeutic option in patients with symptomatic drug-resistant IST/POTS. The aim of this study was to evaluate the long-term rate of redo procedures after hybrid IST ablation and procedural strategy, outcomes and safety of redo procedures. METHODS AND RESULTS: All consecutive patients from 2015 to 2023 were prospectively enrolled in the UZ Brussel monocentric IST/POTS registry. They were analysed if the following inclusion criteria were fulfilled: 1) diagnosis of IST or POTS, 2) symptomatic IST/POTS refractory or intolerant to drugs, and 3) hybrid SN sparing ablation performed. The primary endpoint was redo procedure. The primary safety endpoint was pacemaker (PM) implantation. A total of 220 patients undergone to hybrid IST ablation were included, 185 patients (84.1%) were treated for IST and 61 patients (27.7%) for POTS.After a follow-up of 73.3 ± 16.2 months, 34 patients (15.4%) underwent a redo. A total of 23 patients (67.6%) had a redo for IST recurrence and 11 patients (32.4%) for other arrhythmias. Pacemaker implantation was performed in 21 patients (9.5%). Nine patients (4.1%) had no redo procedure and experienced sick sinus syndrome requiring a PM. Twelve patients (5.4%) received a PM as a shared therapeutic choice combined with SN ablation procedure. CONCLUSION: In a large cohort of patients the long-term free survival from redo procedure after hybrid IST ablation was 84.6% with a low PM implantation rate.


Assuntos
Ablação por Cateter , Taquicardia Sinusal , Humanos , Taquicardia Sinusal/diagnóstico , Taquicardia Sinusal/cirurgia , Taquicardia Sinusal/tratamento farmacológico , Nó Sinoatrial , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Frequência Cardíaca
9.
J Cardiovasc Electrophysiol ; 34(11): 2393-2397, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37792572

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) with thermal energy is characterized by concomitant ablation of the surrounding ganglionated plexi (GP). Pulsed-field ablation (PFA) selectively targets the myocardium and seems associated with only negligible effects on the autonomic nervous system (ANS). However, little is known about the dynamic effects of PFA on the GP immediately after PVI. This study sought to investigate the degree and acute vagal modulation induced by the FarapulseTM PFA system during PVI compared with single-shot thermal ablation. METHODS: A total of 76 patients underwent first-time PVI with either FarapulseTM PFA (PFA group, n = 40) or cryoballoon ablation (thermal ablation group, n = 36) for paroxysmal atrial fibrillation (AF). The effect on the ANS in the two groups was assessed before and after PVI with extracardiac vagal stimulation (ECVS). To capture any transient effects of PFA on the ANS, in a subgroup of PFA patients ECVS was repeated at three predefined timepoints: (1) before PVI (T0); (2) immediately after PVI (T1); and (3) 10 min after the last energy application (T2). RESULTS: Despite similar baseline values, the vagal response induced by ECVS after PVI almost disappeared in the thermal ablation group but persisted in the PFA group (thermal group: 840 [706-1090] ms, p < .001 compared to baseline; PFA group: 11 466 [8720-12 293] ms, p = .70 compared to baseline). Intraprocedural vagal reactions (defined as RR increase >50%, transitory asystole, or atrioventricular block) occurred more frequently with PFA than thermal ablation (70% vs. 28%, p = .001). Moreover, heart rate 24 h post-PVI increased more with thermal ablation than with PFA (16.5 ± 9.0 vs. 2.6 ± 6.1 beats/min, p < .001). In the subgroup of PFA patients undergoing repeated ANS modulation assessment (n = 11), ECVS demonstrated that PFA determined a significant acute suppression of the vagal response immediately after PVI (p < .001 compared to baseline), which recovered almost completely within 10 min. CONCLUSION: PVI with the FarapulseTM PFA system is associated with only transitory and short-lasting vagal effects on the ANS which recover almost completely within a few minutes after ablation. The impact of this phenomenon on AF outcome needs to be further investigated.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Sistema Nervoso Autônomo/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Nervo Vago/cirurgia , Frequência Cardíaca , Ablação por Cateter/efeitos adversos , Resultado do Tratamento
10.
J Clin Med ; 12(19)2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37834900

RESUMO

Previous clinical studies on pulmonary vein isolation (PVI) with radiofrequency balloons (RFB) reported safe and effective procedures for a 20 s RF delivery via posterior electrodes. Recent recommendations from the manufacturer suggest reducing the application time to 15 s on the posterior wall (PW) when facing the esophagus region. Here, we retrospectively assess whether 15 s of RF delivery time on posterior electrodes is safe while still ensuring lesion metrics of sufficient quality. This retrospective study included 133 patients with paroxysmal and persistent atrial fibrillation who underwent PVI using an RFB (Heliostar, Biosense Webster, Inc., Irvine, CA, USA) at two European centers. The ablation protocol was set for an RF duration of 20 s/60 s for the posterior/anterior electrodes. A multielectrode temperature probe was systematically used. In the case of an esophageal temperature rise (ETR) above 42 °C (ETR+), an endoscopic evaluation was performed. All posterior electrode lesion metric dynamics (temperature (T) and impedance (Z)) were collected from the RFB generator and analyzed offline. In total, 2435 posterior electrode applications were analyzed. With an RF delivery of 19.8 (19.7-19.8) s, the median impedance drop was 18.4 (12.2-25.2) Ω, while the temperature rise was 11.1 (7.1-14.9) °C. Accordingly, impedance (84.6 (79.3-90.2) Ω) and temperature plateaus (38 (35.3-41.1) °C) were reached at 13.9 (10.6-16) s and 16.4 (12.6-18.5) s, respectively. Overall, 99.6% and 95.8% of electrodes reached 90% (16.6 Ω) and 95% (17.5 Ω) of their impedance drops within 15 s of RF delivery, while 97.2% and 92.8% achieved 90% (34.2 °C) and 95% (36.1 °C) of their temperature rise to reach the plateaus within 15 s of RF delivery. An ETR >42 °C occurred in 37 (30.1%) patients after 17.7 ± 2.3 s of RF delivery. In the ETR+ group, the impedance drop and temperature rise on the posterior electrodes were higher compared to patients where ETR was <42 °C. Two asymptomatic thermal esophageal injuries were observed. In conclusion, 15 s of RF delivery on the posterior electrodes provides a good balance between safety, with no esophageal temperature rise, and efficacy with high-profile lesion metrics.

11.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37671682

RESUMO

AIMS: Cryoballoon (CB) ablation is the mainstay of single-shot pulmonary vein isolation (PVI). A radiofrequency balloon (RFB) catheter has recently emerged as an alternative. However, these two technologies have not been compared. This study aims to evaluate the freedom from atrial tachyarrhythmias (ATas) at 1 year: procedural characteristics, efficacy, and safety of the novel RFB compared with CB for PVI in patients with paroxysmal atrial fibrillation (AF). METHODS AND RESULTS: This prospective multi-centre study included consecutive patients with symptomatic drug-resistant paroxysmal AF who underwent PVI with RFB or CB between July 2021 and January 2022 from three European centres. A total of 375 consecutive patients were included, 125 in the RFB group and 250 in the CB. Both groups had comparable clinical characteristics. At 12.33 ± 4.91 months, ATas-free rates were 83.20% and 82.00% in the RFB and CB groups, respectively (P > 0.05). Compared with the CB group, the RFB group showed a shorter procedure time [59.91 (45.80-77.12) vs. 77.0 (35.13-122.71) min (P < 0.001)], dwell time [19.59 (14.41-30.24) vs. 27.03 (17.11-57.21) min (P = 0.04)], time to isolation, and thermal energy delivery in all pulmonary veins (P < 0.001). First-pass isolation was comparable. No major complications occurred in either group, with no stroke, atrio-oesophageal fistula, or permanent phrenic nerve injury. Transient phrenic nerve palsy occurred more frequently with CB than RFB (7.20% vs. 3.20%; P = 0.02). Oesophageal temperature rise occurred in 21 (16.8%) patients in the RFB group, and gastroscopy showed erythema in two of them with complete recovery after 30 days. CONCLUSIONS: The RFB appears to have a safety and efficacy profile similar to that of the CB for PVI. Shorter procedural times appear to be driven by shorter left atrial dwell and thermal delivery times.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Fístula Esofágica , Veias Pulmonares , Humanos , Estudos Prospectivos
12.
Artigo em Inglês | MEDLINE | ID: mdl-37756702

RESUMO

OBJECTIVES: Brugada syndrome is a life-threatening disease with an arrhythmogenic substrate located in the epicardium of right ventricle outflow tract. Therefore, the correct region identification is crucial for a successful ablation procedure. Various mapping techniques can be adopted to elaborate this issue, but they were all initially developed for endovascular use. METHODS: In this study, we analysed 21 consecutive hybrid video-assisted thoracoscopic ablation of Brugada syndrome, performed using different mapping systems to identify the ablation target and confirm the elimination of arrhythmogenic substrate; 35 maps have been analysed. RESULTS: Acute success of epicardial right ventricle outflow tract ablation has been achieved in 100% of procedures, no periprocedural complications have been observed; HD Grid catheter showed higher area identification speed and faster fractionated potentials visualization; Rhythmia system has demonstrated the best map density; Carto 3 system showed a significant advantage in patient preparation time, but mapping speed was reduced due to focal catheter use only. CONCLUSIONS: All tested electro anatomical mapping systems can be used for hybrid video-assisted thoracoscopic ablation with same clinical success; however, accuracy and efficacy of mapping systems are heterogenous and highly dependent on proper patient preparation, mapping system and physician skills.

13.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37772950

RESUMO

AIMS: Brugada syndrome (BrS) is a hereditary arrhythmic disease, associated with sudden cardiac death. To date, little is known about the psychosocial correlates and impacts associated with this disease. The aim of this study was to assess a set of patient-reported psychosocial outcomes, to better profile these patients, and to propose a tailored psychosocial care. METHODS AND RESULTS: Patients were recruited at the European reference Centre for BrS at Universitair Ziekenhuis Brussel, Belgium. Recruitment was undertaken in two phases: phase 1 (retrospective), patients with confirmed BrS, and phase 2 (prospective), patients referred for ajmaline testing who had an either positive or negative diagnosis. BrS patients were compared to controls from the general population. Two hundred and nine questionnaires were analysed (144 retrospective and 65 prospective). Collected patient-reported outcomes were on mental health (12 item General Health Questionnaire; GHQ-12), social support (Oslo Social Support Scale), health-related quality of life, presence of Type-D personality (Type-D Scale; DS14), coping styles (Brief-COPE), and personality dimensions (Ten Item Personality Inventory). Results showed higher mental distress (GHQ-12) in BrS patients (2.53 ± 3.03) than in the general population (P < 0.001) and higher prevalence (32.7%) of Type D personality (P < 0.001) in patients with confirmed Brugada syndrome (BrS +). A strong correlation was found in the BrS + group (0.611, P < 0.001) between DS14 negative affectivity subscale and mental distress (GHQ-12). CONCLUSION: Mental distress and type D personality are significantly more common in BrS patients compared to the general population. This clearly illustrates the necessity to include mental health screening and care as standard for BrS.


Assuntos
Síndrome de Brugada , Humanos , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/terapia , Síndrome de Brugada/complicações , Saúde Mental , Estudos Prospectivos , Estudos Retrospectivos , Qualidade de Vida , Medidas de Resultados Relatados pelo Paciente , Eletrocardiografia/métodos
14.
Am J Cardiol ; 207: 100-107, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37734298

RESUMO

Although pulmonary vein (PV) isolation (PVI) is the cornerstone for atrial fibrillation (AF) ablation, no data exist comparing PV anatomy between AF subtypes directly. We aimed to compare PV anatomic characteristics between paroxysmal (PAF) and persistent AF (PeAF) in a matched population using cardiac computed tomography (CCT). Fifty-eight PeAF patients (with CCT prior first AF ablation procedure, absence of valvular disease/previous cardiac intervention), and 58 age-, sex-, body surface area-matched PAF patients were evaluated for left atrial (LA) and PV anatomy: ostial area, ovality index (OVI), transverse/frontal angles. In PeAF vs PAF group, beside higher LA volume index (LAVI), PVs' ostial areas were significantly larger (between 64 - 101 mm2, P < 0.001 for all PVs; remaining valid after LAVI adjustment for left superior [LS], left inferior [LI], and right inferior [RI]PV); left PVs were less oval (0.7 - 0.11 OVI decrease, P =0.039 for LSPV; P = 0.012 for LIPV); LSPV (P = 0.019), LIPV (P < 0.001), RIPV (P = 0.029) were more posteriorly directed; whereas LSPV (P = 0.002), and right superior PV (P = 0.043) were more superiorly directed. Incidence of anatomic variations or early branching was not different. This study showed significant anatomical PV differences between patients with PeAF and PAF, in terms of PV orientation, ostial size and ovality. Anticipating such anatomical differences may aid in choosing the adequate catheter design and technology for PeAF ablation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Radiografia , Átrios do Coração/diagnóstico por imagem , Ablação por Cateter/métodos , Tomografia , Resultado do Tratamento
15.
JACC Clin Electrophysiol ; 9(10): 2096-2105, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37565952

RESUMO

BACKGROUND: Patients with Brugada syndrome (BrS) have an increased risk of arrhythmias, including atrial tachyarrhythmias (ATas). OBJECTIVES: The purpose of this study was to assess underlying atrial cardiomyopathy in BrS and the effect of ajmaline (AJM) test on the atrium of BrS patients using electrocardiogram imaging (ECGI). METHODS: All consecutive patients diagnosed with BrS in a monocentric registry were screened and included if they met the following criteria: 1) BrS diagnosed following current recommendations; and 2) ECGI map performed before and after AJM with a standard protocol. Consecutive patients with no structural heart disease or BrS who had undergone ECGI were included as a control group. Genetic analysis for SCN5A was performed in all BrS patients. Total atrial conduction time (TACT) and local atrial conduction time (LACT) were calculated from atrial ECGI. The primary endpoint was ATas during follow-up. RESULTS: Forty-three consecutive BrS patients and 40 control patients were included. Both TACT and LACT were significantly prolonged in BrS patients compared with control patients. Furthermore, TACT and LACT were significantly higher after AJM administration and in BrS patients who were carriers of a pathogenic/likely pathogenic SCN5A variant. After a mean follow-up of 40.9 months, 6 patients experienced a first ATa occurrence (all in the BrS group, 13.9%). TACT was the only independent predictor of ATas with a cutoff of >138.5 ms (sensitivity 0.92 [95% CI: 0.83-0.98], specificity 0.70 [95% CI: 0.59-0.81]). CONCLUSIONS: ECGI-calculated TACT and LACT are significantly prolonged in BrS patients compared with control patients, and in BrS patients after AJM. This may be consistent with a concealed atrial cardiomyopathy in BrS.


Assuntos
Fibrilação Atrial , Síndrome de Brugada , Cardiomiopatias , Humanos , Síndrome de Brugada/diagnóstico por imagem , Síndrome de Brugada/genética , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Eletrocardiografia/métodos , Ajmalina
17.
J Cardiovasc Med (Hagerstown) ; 24(7): 441-452, 2023 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-37285275

RESUMO

BACKGROUND: In terms of safety and efficacy, cryoballoon ablation (CB-A) has become a valid option for achieving pulmonary vein isolation (PVI) in patients affected by symptomatic atrial fibrillation. However, CB-A data in octogenarians are still scarce and limited to single-centre experiences. The present multicentre study aimed to compare the outcomes and complications of index CB-A in patients older than 80 years with a cohort of younger patients. METHODS AND RESULTS: We retrospectively enrolled 97 consecutive patients aged ≥80 years who underwent PVI using the second-generation CB-A. This group was compared with a younger cohort of patients using a 1:1 propensity score matching. After the matching, 70 patients from the elderly group were analysed and compared with 70 younger patients (control group). The mean age was 81.4 ±â€Š1.9 years among octogenarians and 65.2 ±â€Š10.2 years in the younger cohort. The global success rate after a median follow-up of 23 [18-32.5] months was 60.0% in the elderly group and 71.4% in the control group (P = 0.17). Phrenic nerve palsy was the most common complication occurring in a total of 11 patients (7.9%): in 6 (8.6%) patients in the elderly group and in 5 patients (7.1%) in the younger group (P = 0.51). Only two (1.4%) major complications occurred: one (1.4%) femoral artery pseudoaneurysm in the control group, which resolved with a tight groin bandage, and one (1.4%) case of urosepsis in the elderly group. Arrhythmia recurrence during the blanking period and the need for electrical cardioversion to restore sinus rhythm after PVI were found to be the only independent predictors of late arrhythmia relapses. CONCLUSIONS: The present study showed that CB-A PVI is as feasible, safe and effective among appropriately selected octogenarians as it is in younger patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Idoso de 80 Anos ou mais , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Octogenários , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Pontuação de Propensão , Estudos Retrospectivos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Recidiva , Veias Pulmonares/cirurgia
18.
J Interv Card Electrophysiol ; 66(9): 2135-2142, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37178190

RESUMO

BACKGROUND: The influence of divergent anesthesia types during ablation of premature ventricular complexes (PVCs) is not known. While previously performed under general anesthesia (GA) at our institution, these procedures were exclusively performed under local anesthesia (LA) ± minimal sedation during the COVID-19 outbreak for logistic reasons. METHODS: One hundred and eight consecutive patients (82 GA versus 26 LA) undergoing PVC ablation at our center were evaluated. Intraprocedural PVC burden (over 3 min) pre-ablation was measured twice: (1) at the start (before GA induction) and (2) before catheter insertion (after GA induction). Upon cessation of ablation and after a waiting period of ≥ 15 min, acute ablation success (AAS) was defined as absence of PVCs until the end of the recording period. RESULTS: Intraprocedural PVC burden was not significantly different between LA versus GA group: (1) 17.8 ± 3% vs 12.7 ± 2%, P = 0.17 and (2) 10.0 ± 3% vs 7.4 ± 1%, P = 0.43, respectively. Activation mapping-based ablation was performed significantly more in the LA vs GA group (77% vs 26% of patients, P < 0.001, respectively). AAS was significantly higher in LA vs GA group: 22/26 (85%) vs 41/82 (50%), respectively, P < 0.01. After multivariable analysis, LA was the only independent predictor for AAS (OR 13, 95% CI 1.57-107.4, P = 0.017). CONCLUSION: Ablation of PVC under LA presented significantly higher AAS rate compared to GA. The procedure under GA might be complicated by PVC inhibition (after catheter insertion/during mapping) and PVC disinhibition post-extubation.


Assuntos
Anestésicos , COVID-19 , Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/cirurgia , Ablação por Cateter/métodos , Anestesia Local , Resultado do Tratamento
19.
JACC Clin Electrophysiol ; 9(8 Pt 1): 1296-1306, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37227348

RESUMO

BACKGROUND: Different genes have been associated with idiopathic ventricular fibrillation (IVF); however, there are no studies correlating genotype with phenotype. OBJECTIVES: The aim of this study was to define the genetic background of probands with IVF using large gene panel analysis and to correlate genetics with long-term clinical outcomes. METHODS: All consecutive probands with a diagnosis of IVF were included in a multicenter retrospective study. All patients had: 1) IVF diagnosis throughout the follow-up; and 2) genetic analysis with a broad gene panel. All genetic variants were classified as pathogenic/likely pathogenic (P+), variants of unknown significance (VUS) or no variants (NO-V), following current guidelines of the American College of Medical Genetics and Genomics and the Association for Molecular Pathology. The primary endpoint was occurrence of ventricular arrhythmias (VA). RESULTS: Forty-five consecutive patients were included. A variant was found in 12 patients, 3 P+ and 9 VUS carriers. After a mean follow-up time of 105.0 months, there were no deaths and 16 patients (35.6%) experienced a VA. NO-V patients had higher VA free survival during the follow-up, compared with both VUS (72.7% vs 55.6%, log-rank P < 0.001) and P+ (72.7% vs 0%, log-rank P = 0.013). At Cox analysis, P+ or VUS carrier status was a predictor of VA occurrence. CONCLUSIONS: In probands with IVF, undergoing genetic analysis with a broad panel, the diagnostic yield for P+ is 6.7%. P+ or VUS carrier status is a predictor of VA occurrence.


Assuntos
Testes Genéticos , Fibrilação Ventricular , Humanos , Estudos Retrospectivos , Arritmias Cardíacas/complicações
20.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37246904

RESUMO

AIMS: Hybrid atrial fibrillation (AF) ablation is a promising approach in non-paroxysmal AF. The aim of this study is to assess the long-term outcomes of hybrid ablation in a large cohort of patients after both an initial and as a redo procedure. METHODS AND RESULTS: All consecutive patients undergoing hybrid AF ablation at UZ Brussel from 2010 to 2020 were retrospectively evaluated. Hybrid AF ablation was performed in a one-step procedure: (i) thoracoscopic ablation followed by (ii) endocardial mapping and eventual ablation. All patients received PVI and posterior wall isolation. Additional lesions were performed based on clinical indication and physician judgement. Primary endpoint was freedom from atrial tachyarrhythmias (ATas). A total of 120 consecutive patients were included, 85 patients (70.8%) underwent hybrid AF ablation as first procedure (non-paroxysmal AF 100%), 20 patients (16.7%) as second procedure (non-paroxysmal AF 30%), and 15 patients (12.5%) as third procedure (non-paroxysmal AF 33.3%). After a mean follow-up of 62.3 months ± 20.3, a total of 63 patients (52.5%) experienced ATas recurrence. Complications occurred in 12.5% of patients. There was no difference in ATas between patients undergoing hybrid as first vs. redo procedure (P = 0.53). Left atrial volume index and recurrence during blanking period were independent predictors of ATas recurrence. CONCLUSION: In a large cohort of patients undergoing hybrid AF ablation, the survival from ATas recurrence was 47.5% at ≈5 years follow-up. There was no difference in clinical outcomes between patients undergoing hybrid AF ablation as first procedure or as a redo.


Assuntos
Técnicas de Ablação , Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Seguimentos , Átrios do Coração , Estudos Retrospectivos , Taquicardia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...